AJR Am J Roentgenol ; 2023 Oct 25.
Article in English | MEDLINE | ID: mdl-37877595

ABSTRACT

Current CT oral contrast agents improve the conspicuity and confidence for bowel and peritoneal findings in many clinical scenarios, particularly for outpatient and oncologic abdominopelvic imaging. Yet, existing positive and neutral oral contrast agents may diminish the detectability of certain radiologic findings, frequently in the same scans in which the oral contrast agent improves the detectability of other findings. With ongoing improvements in CT technology, particularly multi-energy CT, opportunities are opening for new types of oral contrast agents to further improve anatomic delineation and disease detection using CT. The CT signal of new dark oral contrast agents and of new high-Z oral contrast agents promise to combine the strengths of both positive and neutral oral CT contrast agents by providing distinct CT appearances in comparison with bodily tissues, iodinated IV contrast agents, and other classes of new CT contrast agents. High-Z oral contrast agents will unlock previously inaccessible capabilities of multi-energy CT, particularly photon-counting detector CT, for differentiating simultaneously administered IV and oral contrast agents; this technique will allow generation of rich 3D, intuitive, perfectly co-registered, high-resolution image sets with individual contrast-agent "colors" that provide compelling clarity for intertwined intraabdominal anatomy and disease processes.

2.
Radiol Clin North Am ; 61(6): 1031-1049, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37758355

ABSTRACT

The use of dual-energy computed tomography (CT) allows for reconstruction of energy- and material-specific image series. The combination of low-energy monochromatic images, iodine maps, and virtual unenhanced images can improve lesion detection and disease characterization in the gastrointestinal tract in comparison with single-energy CT.

3.
Radiol Clin North Am ; 61(6): 945-961, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37758362

ABSTRACT

Compared to conventional single-energy CT (SECT), dual-energy CT (DECT) provides additional information to better characterize imaged tissues. Approaches to DECT acquisition vary by vendor and include source-based and detector-based systems, each with its own advantages and disadvantages. Despite the different approaches to DECT acquisition, the most utilized DECT images include routine SECT equivalent, virtual monoenergetic, material density (eg, iodine map), and virtual non-contrast images. These images are generated either through reconstructions in the projection or image domains. Designing and implementing an optimal DECT workflow into routine clinical practice depends on radiologist and technologist input with special considerations including appropriate patient and protocol selection and workflow automation. In addition to better tissue characterization, DECT provides numerous advantages over SECT such as the characterization of incidental findings and dose reduction in radiation and iodinated contrast.


Subject(s)
Iodine , Radiography, Dual-Energy Scanned Projection , Humans , Tomography, X-Ray Computed/methods , Contrast Media , Radiation Dosage , Radiography, Dual-Energy Scanned Projection/methods
5.
Radiographics ; 43(6): e220181, 2023 06.
Article in English | MEDLINE | ID: mdl-37227944

ABSTRACT

Quantitative imaging biomarkers of liver disease measured by using MRI and US are emerging as important clinical tools in the management of patients with chronic liver disease (CLD). Because of their high accuracy and noninvasive nature, in many cases, these techniques have replaced liver biopsy for the diagnosis, quantitative staging, and treatment monitoring of patients with CLD. The most commonly evaluated imaging biomarkers are surrogates for liver fibrosis, fat, and iron. MR elastography is now routinely performed to evaluate for liver fibrosis and typically combined with MRI-based liver fat and iron quantification to exclude or grade hepatic steatosis and iron overload, respectively. US elastography is also widely performed to evaluate for liver fibrosis and has the advantage of lower equipment cost and greater availability compared with those of MRI. Emerging US fat quantification methods can be performed along with US elastography. The author group, consisting of members of the Society of Abdominal Radiology (SAR) Liver Fibrosis Disease-Focused Panel (DFP), the SAR Hepatic Iron Overload DFP, and the European Society of Radiology, review the basics of liver fibrosis, fat, and iron quantification with MRI and liver fibrosis and fat quantification with US. The authors cover technical requirements, typical case display, quality control and proper measurement technique and case interpretation guidelines, pitfalls, and confounding factors. The authors aim to provide a practical guide for radiologists interpreting these examinations. © RSNA, 2023 See the invited commentary by Ronot in this issue. Quiz questions for this article are available in the supplemental material.


Subject(s)
Elasticity Imaging Techniques , Iron Overload , Liver Diseases , Humans , Iron , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/pathology , Liver/diagnostic imaging , Liver/pathology , Magnetic Resonance Imaging/methods , Liver Diseases/pathology , Iron Overload/diagnostic imaging , Elasticity Imaging Techniques/methods , Radiologists , Biomarkers
6.
Diagnostics (Basel) ; 12(9)2022 Sep 05.
Article in English | MEDLINE | ID: mdl-36140556

ABSTRACT

Purpose: To assess the influence of different dual-energy CT (DECT) scanner techniques on the severity of visceral-motion-related artifacts on the liver. Methods: Two independent readers retrospectively evaluated visceral-motion-related artifacts on the liver on 120-kVp(-like), monoenergetic low- and high-keV, virtual non-contrast (VNC), and iodine images acquired on a dual-source, twin-beam, fast kV-switching, and dual-layer spectral detector scanner. Quantitative assessment: Depth of artifact extension into the liver, measurements of Hounsfield Units (HU) and iodine concentrations. Qualitative assessment: Five-point Likert scale (1 = none to 5 = severe). Artifact severity between image reconstructions were compared by Wilcoxon signed-rank and paired t-tests. Results: 615 contrast-enhanced routine clinical DECT scans of the abdomen were evaluated in 458 consecutive patients (mean age: 61 ± 14 years, 331 men). For dual-source and twin-beam scanners, depth of extension of artifacts into the liver was significantly shorter and artifact severity scores significantly lower for 120-kVp-like images compared with the other image reconstructions (p < 0.001, each). For fast kV-switching and spectral detector scanner images, depth of extension of artifacts was significantly shorter and artifact severity scores significantly lower for iodine images (p < 0.001, each). Dual-source 120-kVp-like and spectral detector iodine images reduced artifacts to an extent that no significant difference in HU or iodine concentrations between artifacts (dual-source: 97 HU, spectral detector: 1.9 mg/mL) and unaffected liver parenchyma (dual-source: 108 HU, spectral detector: 2.1 mg/mL) was measurable (dual-source: p = 0.32, spectral detector: p = 0.15). Conclusion: Visceral-motion-related artifacts on the liver can be markedly reduced by viewing 120-kVp-like images for dual-source and twin-beam DECT scanners and iodine images for fast kV-switching and dual-layer spectral detector DECT scanners.

7.
Radiol Clin North Am ; 60(5): 731-743, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35989041

ABSTRACT

Dual-energy computed tomography (DECT) increases confidence in hepatobiliary computed tomography (CT) evaluation by boosting visible iodine enhancement and differentiating between materials based on relative attenuation of 2 different X-ray energy spectra. Image reconstructions from DECT scans improve the detection and characterization of focal liver lesions, allows for quantification of diffuse liver disease, and reveals gallstones that may be missed on standard CT imaging. Our article aims to illustrate the basic concepts of DECT and types of image reconstruction relevant for the assessment of hepatobiliary diseases. We then review literature on the use of DECT for evaluating focal and diffuse hepatobiliary diseases.


Subject(s)
Iodine , Liver Diseases , Radiography, Dual-Energy Scanned Projection , Contrast Media , Humans , Image Processing, Computer-Assisted/methods , Liver Diseases/diagnostic imaging , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods
8.
Radiol Clin North Am ; 60(5): xv-xvi, 2022 09.
Article in English | MEDLINE | ID: mdl-35989050

Subject(s)
Diagnostic Imaging , Humans
9.
Diagnostics (Basel) ; 12(4)2022 Mar 23.
Article in English | MEDLINE | ID: mdl-35453830

ABSTRACT

Background: Peristalsis-related streak artifacts on the liver compromise image quality and diagnostic accuracy. Purpose: To assess dual-layer spectral-detector computed tomography (CT) image reconstructions for reducing intestinal peristalsis-related streak artifacts on the liver. Methods: We retrospectively evaluated 220 contrast-enhanced abdominal dual-energy CT scans in 131 consecutive patients (mean age: 68 ± 10 years, 120 men) who underwent routine clinical dual-layer spectral-detector CT imaging (120 kVp, 40 keV, 200 keV, virtual non-contrast (VNC), iodine images). Two independent readers evaluated bowel peristalsis streak artifacts on the liver qualitatively on a five-point Likert scale (1 = none to 5 = severe) and quantitatively by depth of streak artifact extension into the liver and measurements of Hounsfield Unit and iodine concentration differences from normal liver. Artifact severity between image reconstructions were compared by Wilcoxon signed-rank and paired t-tests. Results: 12 scans were excluded due to missing spectral data, artifacts on the liver originating from metallic foreign materials, or oral contrast material. Streak artifacts on the liver were seen in 51/208 (25%) scans and involved the left lobe only in 49/51 (96%), the right lobe only in 0/51 (0%), and both lobes in 2/51 (4%) scans. Artifact frequency was lower in iodine than in 120 kVp images (scans 18/208 vs. 51/208, p < 0.001). Artifact severity was less in iodine than in 120 kVp images (median score 1 vs. 3, p < 0.001). Streak artifact extension into the liver was shorter in iodine than 120 kVp images (mean length 2 ± 4 vs. 12 ± 5 mm, p < 0.001). Hounsfield Unit and iodine concentration differed significantly between bright streak artifacts and normal liver in 120 kVp, 40 keV, 200 keV, and VNC images (p < 0.001, each), but not in iodine images (p = 0.23). Conclusion: Intestinal peristalsis-related streak artifacts commonly affect the left liver lobe at CT and can be substantially reduced by viewing iodine dual-energy CT image reconstructions.

10.
Eur Radiol ; 32(11): 7936-7945, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35486170

ABSTRACT

OBJECTIVES: To compare the performance of conventional versus spectral-based electronic stool cleansing for iodine-tagged CT colonography (CTC) using a dual-layer spectral detector scanner. METHODS: We retrospectively evaluated iodine contrast stool-tagged CTC scans of 30 consecutive patients (mean age: 69 ± 8 years) undergoing colorectal cancer screening obtained on a dual-layer spectral detector CT scanner. One reader identified locations of electronic cleansing artifacts (n = 229) on conventional and spectral cleansed images. Three additional independent readers evaluated these locations using a conventional cleansing algorithm (Intellispace Portal) and two experimental spectral cleansing algorithms (i.e., fully transparent and translucent tagged stool). For each cleansed image set, readers recorded the severity of over- and under-cleansing artifacts on a 5-point Likert scale (0 = none to 4 = severe) and readability compared to uncleansed images. Wilcoxon's signed-rank tests were used to assess artifact severity, type, and readability (worse, unchanged, or better). RESULTS: Compared with conventional cleansing (66% score ≥ 2), the severity of overall cleansing artifacts was lower in transparent (60% score ≥ 2, p = 0.011) and translucent (50% score ≥ 2, p < 0.001) spectral cleansing. Under-cleansing artifact severity was lower in transparent (49% score ≥ 2, p < 0.001) and translucent (39% score ≥ 2, p < 0.001) spectral cleansing compared with conventional cleansing (60% score ≥ 2). Over-cleansing artifact severity was worse in transparent (17% score ≥ 2, p < 0.001) and translucent (14% score ≥ 2, p = 0.023) spectral cleansing compared with conventional cleansing (9% score ≥ 2). Overall readability was significantly improved in transparent (p < 0.001) and translucent (p < 0.001) spectral cleansing compared with conventional cleansing. CONCLUSIONS: Spectral cleansing provided more robust electronic stool cleansing of iodine-tagged stool at CTC than conventional cleansing. KEY POINTS: • Spectral-based electronic cleansing of tagged stool at CT colonography provides higher quality images with less perception of artifacts than does conventional cleansing. • Spectral-based electronic cleansing could potentially advance minimally cathartic approach for CT colonography. Further clinical trials are warranted.


Subject(s)
Colonography, Computed Tomographic , Iodine , Humans , Middle Aged , Aged , Colonography, Computed Tomographic/methods , Retrospective Studies , Algorithms , Cathartics , Artifacts
11.
AJR Am J Roentgenol ; 219(2): 233-243, 2022 08.
Article in English | MEDLINE | ID: mdl-35293233

ABSTRACT

BACKGROUND. Data are limited regarding utility of positive oral contrast material for peritoneal tumor detection on CT. OBJECTIVE. The purpose of this article is to compare positive versus neutral oral contrast material for detection of malignant deposits in nonsolid intraabdominal organs on CT. METHODS. This retrospective study included 265 patients (133 men, 132 women; median age, 61 years) who underwent an abdominopelvic CT examination in which the report did not suggest presence of malignant deposits and a subsequent CT examination within 6 months in which the report indicated at least one unequivocal malignant deposit. Examinations used positive (iohexol; n = 100) or neutral (water; n = 165) oral agents. A radiologist reviewed images to assess whether the deposits were visible (despite clinical reports indicating no deposits) on unblinded comparison with the follow-up examinations; identified deposits were assigned to one of seven intraabdominal compartments. The radiologist also assessed adequacy of bowel filling with oral contrast material. Two additional radiologists independently reviewed examinations in blinded fashion for malignant deposits. NPV was assessed of clinical CT reports and blinded retrospective readings for detection of malignant deposits visible on unblinded comparison with follow-up examinations. RESULTS. Unblinded review identified malignant deposits in 58.1% (154/265) of examinations. In per-patient analysis of clinical reports, NPV for malignant deposits was higher for examinations with adequate bowel filling with positive oral contrast material (65.8% [25/38]) than for examinations with inadequate bowel filling with positive oral contrast material (45.2% [28/62], p = .07) or with neutral oral contrast material regardless of bowel filling adequacy (35.2% [58/165], p = .002). In per-compartment analysis of blinded interpretations, NPV was higher for examinations with adequate and inadequate bowel filling with positive oral contrast material than for examinations with neutral oral contrast regardless of bowel filling adequacy (reader 1: 94.7% [234/247] and 92.5% [382/413] vs 88.3% [947/1072], both p = .045; reader 2: 93.1% [228/245] and 91.6% [361/394] vs 85.9% [939/1093], both p = .01). CONCLUSION. CT has suboptimal NPV for malignant deposits in intraabdominal nonsolid organs. Compared with neutral material, positive oral contrast material improves detection, particularly with adequate bowel filling. CLINICAL IMPACT. Optimization of bowel preparation for oncologic CT may help avoid potentially severe clinical consequences of missed malignant deposits.


Subject(s)
Contrast Media , Tomography, X-Ray Computed , Female , Humans , Intestines , Iohexol , Male , Middle Aged , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
12.
Eur Radiol ; 32(7): 4749-4759, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35083528

ABSTRACT

OBJECTIVES: To investigate the differentiation of premalignant from benign colorectal polyps detected by CT colonography using deep learning. METHODS: In this retrospective analysis of an average risk colorectal cancer screening sample, polyps of all size categories and morphologies were manually segmented on supine and prone CT colonography images and classified as premalignant (adenoma) or benign (hyperplastic polyp or regular mucosa) according to histopathology. Two deep learning models SEG and noSEG were trained on 3D CT colonography image subvolumes to predict polyp class, and model SEG was additionally trained with polyp segmentation masks. Diagnostic performance was validated in an independent external multicentre test sample. Predictions were analysed with the visualisation technique Grad-CAM++. RESULTS: The training set consisted of 107 colorectal polyps in 63 patients (mean age: 63 ± 8 years, 40 men) comprising 169 polyp segmentations. The external test set included 77 polyps in 59 patients comprising 118 polyp segmentations. Model SEG achieved a ROC-AUC of 0.83 and 80% sensitivity at 69% specificity for differentiating premalignant from benign polyps. Model noSEG yielded a ROC-AUC of 0.75, 80% sensitivity at 44% specificity, and an average Grad-CAM++ heatmap score of ≥ 0.25 in 90% of polyp tissue. CONCLUSIONS: In this proof-of-concept study, deep learning enabled the differentiation of premalignant from benign colorectal polyps detected with CT colonography and the visualisation of image regions important for predictions. The approach did not require polyp segmentation and thus has the potential to facilitate the identification of high-risk polyps as an automated second reader. KEY POINTS: • Non-invasive deep learning image analysis may differentiate premalignant from benign colorectal polyps found in CT colonography scans. • Deep learning autonomously learned to focus on polyp tissue for predictions without the need for prior polyp segmentation by experts. • Deep learning potentially improves the diagnostic accuracy of CT colonography in colorectal cancer screening by allowing for a more precise selection of patients who would benefit from endoscopic polypectomy, especially for patients with polyps of 6-9 mm size.


Subject(s)
Colonic Polyps , Colonography, Computed Tomographic , Colorectal Neoplasms , Deep Learning , Precancerous Conditions , Aged , Colonic Polyps/diagnostic imaging , Colonography, Computed Tomographic/methods , Colonoscopy , Colorectal Neoplasms/diagnostic imaging , Humans , Male , Middle Aged , Precancerous Conditions/diagnostic imaging , Retrospective Studies , Sensitivity and Specificity
13.
Abdom Radiol (NY) ; 47(5): 1660-1683, 2022 05.
Article in English | MEDLINE | ID: mdl-34191075

ABSTRACT

Acute bowel ischemia is a condition with high mortality and requires rapid intervention to avoid catastrophic outcomes. Swift and accurate imaging diagnosis is essential because clinical findings are commonly nonspecific. Conventional contrast enhanced CT of the abdomen has been the imaging modality of choice to evaluate suspected acute bowel ischemia. However, subtlety of image findings and lack of non-contrast or arterial phase images can make correct diagnosis challenging. Dual-energy CT provides valuable information toward assessing bowel ischemia. Dual-energy CT exploits the differential X-ray attenuation at two different photon energy levels to characterize the composition of tissues and reveal the presence or absence of faint intravenous iodinated contrast to improve reader confidence in detecting subtle bowel wall enhancement. With the same underlying technique, virtual non-contrast images can help to show non-enhancing hyperdense hemorrhage of the bowel wall in intravenous contrast-enhanced scans without the need to acquire actual non-contrast scans. Dual-energy CT derived low photon energy (keV) virtual monoenergetic images emphasize iodine contrast and provide CT angiography-like images from portal venous phase scans to better evaluate abdominal arterial patency. In Summary, dual-energy CT aids diagnosing acute bowel ischemia in multiple ways, including improving visualization of the bowel wall and mesenteric vasculature, revealing intramural hemorrhage in contrast enhanced scans, or possibly reducing intravenous contrast dose.


Subject(s)
Iodine Compounds , Iodine , Mesenteric Ischemia , Contrast Media , Humans , Ischemia/diagnostic imaging , Tomography, X-Ray Computed/methods
14.
AJR Am J Roentgenol ; 218(2): 290-299, 2022 02.
Article in English | MEDLINE | ID: mdl-34406059

ABSTRACT

BACKGROUND. The value of dual-energy CT (DECT) for bowel wall assessment is increasingly recognized. Although technical improvements reduce peristalsis artifact in conventional CT, the effects of peristalsis on DECT image reconstructions remain poorly studied. OBJECTIVE. The purpose of this study was to evaluate the influence of different DECT scanners and enteric contrast agents on the severity of bowel peristalsis artifact in vitro. METHODS. To simulate bowel peristalsis, a 3-cm-diameter corrugated hollow tube representing the bowel was oscillated constantly in the z-axis within a larger water-filled cylinder. The bowel was serially filled with air, water, and iodinated or experimental dark contrast material and scanned on four different DECT platforms (spectral detector, rapid peak kilovoltage switching, split filter, and dual source) to reconstruct 120-kVp-like and iodine images. Two readers rated each image reconstruction for artifact severity from 0 (none) to 3 (severe) and recorded the degree to which iodine images depicted bowel wall hyperattenuation on 120-kVp-like images as artifactual. Artifact severity scores were compared by ANOVA with Bonferroni correction. RESULTS. Interrater agreement on artifact scores was excellent (intraclass correlation coefficient, 0.82 [95% CI, 0.79-0.84]). For 120-kVp-like images, mean peristalsis artifact scores were lower (all p < .001) for split-filter (1.47) and dual-source (1.86) scanners than for spectral-detector (2.58) and rapid-kilovoltage-switching (2.74) scanners. Compared with those on 120-kVp images, peristalsis artifacts on iodine images were less severe for spectral-detector (score, 1.03; p < .001) and rapid-kilovoltage-switching (2.09; p < .001) systems but more severe for dual-source (2.77; p < .001) and split-filter (2.62; p < .001) systems. Peristalsis artifact was rated less severe with experimental dark bowel contrast medium (score, 1.79) than with other bowel contrast agents (all p < .001). Iodine images helped identify bowel wall hyperattenuation as artifactual in 94.7% of reviewed cases for spectral-detector and 40.7% of cases for rapid-kilovoltage-switching scanners. CONCLUSION. For spectral-detector and rapid-kilovoltage-switching DECT, iodine images minimize peristalsis artifact, but for dual-source and split-filter DECT, mixed 120-kVp-like images are preferred. Compared with iodinated contrast material and water, experimental dark bowel contrast material reduces peristalsis artifact. CLINICAL IMPACT. Knowledge of the preferred images for reducing peristalsis artifact can lessen the effect of peristalsis on clinical DECT interpretation. Dark enteric contrast agents, when they become clinically available, may further reduce the effects of peristalsis.


Subject(s)
Artifacts , Contrast Media , Peristalsis , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , In Vitro Techniques , Phantoms, Imaging
15.
Magn Reson Imaging Clin N Am ; 29(3): 305-320, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34243919

ABSTRACT

Computed tomography (CT) is often performed as the initial imaging study for the workup of patients with known or suspected liver disease. Our article reviews liver CT techniques and protocols in clinical practice along with updates on relevant CT advances, including wide-detector CT, radiation dose optimization, and multienergy scanning, that have already shown clinical impact. Particular emphasis is placed on optimizing the late arterial phase of enhancement, which is critical to evaluation of hepatocellular carcinoma. We also discuss emerging techniques that may soon influence clinical care.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Carcinoma, Hepatocellular/diagnostic imaging , Contrast Media , Humans , Liver Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Tomography, X-Ray Computed
17.
J Magn Reson Imaging ; 54(3): 728-736, 2021 09.
Article in English | MEDLINE | ID: mdl-33665942

ABSTRACT

BACKGROUND: MR enterography (MRE) is generally performed without bowel preparation, but the frequency and extent by which bowel contents affect bowel wall visualization are poorly described in the literature. PURPOSE: To evaluate MRE bowel wall visualization quality relative to bowel lumen contents and patient demographics. STUDY TYPE: Retrospective, single-center. POPULATION: One hundred and four consecutive patients (mean age 29 years, range 5-76 years) without prior bowel resection who had undergone MRE. FIELD STRENGTH/SEQUENCE: 3 T (N = 87) or 1.5 T (N = 17)/T2-weighted single-shot spin echo (T2WI) and fat-saturated T1-weighted gradient echo (T1WI) without and with gadolinium. ASSESSMENT: For the proximal and distal jejunum and ileum and colon, three readers independently categorized bowel lumen signal (water = bright T2 dark T1, T1-bright, or air = dark T2 and T1 signal) and scored distension (0 = poor, 1 = moderate, 2 = well) and wall enhancement (0 = unclear, 1 = perceptible, 2 = clear) based upon gadolinium enhanced T1WI for the 104 MRE exams). The bowel visualization score was the sum of the wall enhancement and distension scores and was considered adequate if ≥3. STATISTICAL TESTS: Wilcoxon signed-rank test. RESULTS: The bowel lumen content was water signal in 93% (97/104 scans), 92% (95/104), 98% (102/104), and 93% (92/104) of the proximal and distal jejunum and proximal and distal ileum, respectively, but only in 12.5% (13/104) of the colon. There was adequate bowel visualization of 53.8%, 77.8%, 84.6%, 90.4% of the proximal and distal jejunum and proximal and distal ileum, respectively, but only 19.2% of the colon. In children (age < 18 years), the visualization score of the ileum was lower when the adjacent colon contained air (2.4 ± 0.97) compared to water (3.75 ± 0.29, P < 0.05) or T1-bright material (3.21 ± 0.82, P < 0.05). DATA CONCLUSION: Without bowel preparation, colon wall visualization was often unsatisfactory at MRE, and air-filled colon also degraded small bowel visualization, particularly in children. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 1.


Subject(s)
Contrast Media , Magnetic Resonance Imaging , Adolescent , Adult , Aged , Child , Child, Preschool , Demography , Gadolinium , Humans , Middle Aged , Retrospective Studies , Young Adult
18.
Top Magn Reson Imaging ; 30(1): 3-11, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33528207

ABSTRACT

ABSTRACT: Magnetic resonance enterography (MRE) is a well-established imaging technique that is commonly used for evaluating a variety of bowel diseases, most commonly inflammatory bowel disease which is increasing in prevalence. Inflammatory bowel disease is composed of 2 related, but distinct disease entities: Crohn disease (CD) and ulcerative colitis. In ulcerative colitis, inflammation is generally limited to the mucosa and invariably involves the rectum, and often the more proximal colon. CD is typified by transmural inflammation with skip lesions occurring anywhere from the mouth to anus, but characteristically involves the terminal ileum. The transmural involvement of CD may lead to debilitating ulceration and, ultimately, development of sinus tracts, which can be associated with abscesses and fistulae as extraenteric manifestations of the disease. Because much of the small bowel and extraenteric disease cannot be adequately assessed with conventional endoscopy, imaging plays a crucial role in initial diagnosis and follow-up. MRE does not use ionizing radiation which is important for these patients, many of which present earlier in life and may require multiple imaging examinations. In this article, we review the clinical indications, patient preparation, and optimal technique for MRE. We also discuss the role and proper selection of intravenous gadolinium-based contrast material, oral contrast material, and antiperistaltic agents, including pediatric considerations. Finally, we review the recommended and optional pulse sequence selection, including discussion of a "time-efficient" protocol, reviewing their utility, advantages, and limitations. Our hope is to aid the radiologist seeking to develop a robust MRE imaging program for the evaluation of bowel disease.


Subject(s)
Gastrointestinal Tract/diagnostic imaging , Magnetic Resonance Imaging/methods , Contrast Media , Humans
19.
Radiographics ; 41(2): 509-523, 2021.
Article in English | MEDLINE | ID: mdl-33606565

ABSTRACT

Dual-energy CT (DECT) is an exciting innovation in CT technology with profound capabilities to improve diagnosis and add value to patient care. Significant advances in this technology over the past decade have improved our ability to successfully adopt DECT into the clinical routine. To enable effective use of DECT, one must be aware of the pitfalls and artifacts related to this technology. Understanding the underlying technical basis of artifacts and the strategies to mitigate them requires optimization of scan protocols and parameters. The ability of radiologists and technologists to anticipate their occurrence and provide recommendations for proper selection of patients, intravenous and oral contrast media, and scan acquisition parameters is key to obtaining good-quality DECT images. In addition, choosing appropriate reconstruction algorithms such as image kernel, postprocessing parameters, and appropriate display settings is critical for preventing quantitative and qualitative interpretive errors. Therefore, knowledge of the appearances of these artifacts is essential to prevent errors and allows maximization of the potential of DECT. In this review article, the authors aim to provide a comprehensive and practical overview of possible artifacts that may be encountered at DECT across all currently available commercial clinical platforms. They also provide a pictorial overview of the diagnostic pitfalls and outline strategies for mitigating or preventing the occurrence of artifacts, when possible. The broadening scope of DECT applications necessitates up-to-date familiarity with these technologies to realize their full diagnostic potential.


Subject(s)
Artifacts , Radiography, Dual-Energy Scanned Projection , Algorithms , Contrast Media , Humans , Tomography, X-Ray Computed
20.
Radiographics ; 41(1): 98-119, 2021.
Article in English | MEDLINE | ID: mdl-33411614

ABSTRACT

Dual-energy CT (DECT) is a tremendous innovation in CT technology that allows creation of numerous imaging datasets by enabling discrete acquisitions at more than one energy level. The wide range of images generated from a single DECT acquisition provides several benefits such as improved lesion detection and characterization, superior determination of material composition, reduction in the dose of iodine, and more robust quantification. Technological advances and the proliferation of various processing methods have led to the availability of diverse vendor-based DECT approaches, each with a different acquisition and image reconstruction process. The images generated from various DECT scanners differ from those from conventional single-energy CT because of differences in their acquisition techniques, material decomposition methods, image reconstruction algorithms, and postprocessing methods. DECT images such as virtual monochromatic images, material density images, and virtual unenhanced images have different imaging appearances, texture features, and quantitative capabilities. This heterogeneity creates challenges in their routine interpretation and has certain associated pitfalls. Some artifacts such as residual iodine on virtual unenhanced images and an appearance of pseudopneumatosis in a gas-distended bowel loop on material-density iodine images are specific to DECT, while others such as pseudoenhancement seen on virtual monochromatic images are also observed at single-energy CT. Recognizing the potential pitfalls associated with DECT is necessary for appropriate and accurate interpretation of the results of this increasingly important imaging tool. Online supplemental material is available for this article. ©RSNA, 2021.


Subject(s)
Iodine , Radiography, Dual-Energy Scanned Projection , Artifacts , Humans , Image Processing, Computer-Assisted , Tomography, X-Ray Computed